GB
14
WIKA operating instructions bypass level indicator model BNA
112195.01 11/2012 GB/D
Attachment example (magnetic switch to support bar)
These magnetic switches are xed to a separately attached
support bar (g. 4).
■
Remove the support bar (1) by loosening the mounting screws (2) and
removing the retaining plates (3) from the bypass stand seat
■
Push the magnetic switch (4) onto the support bar (1)
■
Attach the support bar (1) to the bypass tube (5) again using the
retaining plates (3) and mounting screws (2)
■
Push the magnetic switch to the height of the required switch point
and x in place by tightening the screws (6) (the switch point is
marked on the product label)
Please make sure during mounting that the cable entry and/
or the plug are pointing downwards. To guarantee a safe
switching function, the magnetic switch housing must rest
against the bypass tube.
3. Installation and commissioning
Fig. 4: Mounting the magnetic switch (model MS, MV, MVT, MEx)
Comentarios a estos manuales