WIKA operating instructions level sensor model FFG
7
13445627.01 12/2010 GB/D/F
The level sensor shown in gure 2 serves for the continuous
measurement of uids. To transmit the liquid level value to the sensor, a
oat is sliding on the sensor tube. The operating principle of the sensor
is based on the magnetostriction eect. The oat contains a magnet
while a wire made of magnetostrictive material is installed under tension
inside the sensor tube. The magnetic eld of the oat is twisting the
wire. A second, temporary magnetic eld is generated along the wire by
a current pulse within the wire. The superposition of the two magnetic
elds will release a mechanical wave on the wire.
At the end of the wire within the sensor head, the mechanical wave is
converted by a piezo-ceramic transducer into an electrical signal. The
starting point of the mechanical wave and, hence, the oat position is
then determined by measuring the transit time.
The results of such measurements are feasibility-tested by a microcon-
troller located in the sensor head and are then converted into a current
value by a digital analog transformer. The sensor is provided with a
2-wire connection so that the current consumption indicates the position
of the oat at the same time. The current values are restricted to a range
of between 3.5 ... 23 mA.