Wika UT-11 Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
Published 16.2.04
C
Universal Pressure Transmitter UniTrans
Technical Data
Subject to change due to technical modifications. © Copyright WIKA Alexander Wiegand GmbH & Co. KG / BRD
WIKA Alexander Wiegand GmbH & Co. KG · Alexander-Wiegand-Str. · 63911 Klingenberg · (09372) 132 - 710 · Fax - 706 · E-mail: support-tronic@wika.de · www.wika.de
52
3.4 Auxilliary Power
3.5 Ambient Conditions
3.6 Process Conditions
Electrical connection
per EN 60 529/ IEC529
M 20 x 1.5 cable
g
land with internal ter-
minal block (see 4.4)
M12x1 plu
g
, 4-pin (pin allocation: 1+ 3-)
[3/4" NPT female conduit (onl
y
with alu-
minium case)]
Electric protection Reverse polarit
y
, overload and short cir-
cuit protection
Power suppl
y
12 ... 36 V DC
Ambient temperature 40 °C ... + 85 °C
( 20 °C ... 70 °C with displa
y
)
Stora
g
e temperature 40 °C ... + 85 °C
( 35 °C ... 80 °C with displa
y
)
Climate class D per DIN IEC 654-1
In
g
ress protection per EN 60 529 IP 65 with plastic case
IP 67 with aluminum case
-conformit
y
Interference emission and immunit
y
see EN 61326
(also fulfills NAMUR NE 21)
97/23 EG Pressure Equipment Direc-
tive (Module H)
Medium temperature
G 1 1/2
G 1 EHEDG with coolin
g
element
30 °C ... + 105 °C
(up to 30 min. 140 °C at an ambient
temperature of < 50 °C
-30 °C ... + 150 °C
°F = (°C * 1.8) + 32
°F = (°C * 1.8) + 32
Vista de pagina 12