GB
3. Technical data
3.4 Model PGT23.100 / PGT23.160
Working pressure
- Steady Full scale range
- Fluctuating 0.9 x full scale range
- Transient 1.3 x full scale range
Temperature influence
max. ± 0.4 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP protection class
- Housing IP 54 per EN 60 529 / IEC 60 529
- With liquid filling IP 65
Permissible temperatures
- Ambient filled/unfilled -40 ... +60 °C
- Medium maximum +100 °C
Further technical data see data sheet PV 12.04
3.5 Model PGT43.100 / PGT43.160
Working pressure
- Steady Full scale range
- Fluctuating 0.9 x full scale range
- Transient 5 x full scale range, however max. 40 bar
Temperature influence
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP protection class
- Housing IP 54 per EN 60 529 / IEC 60 529
- With liquid filling IP 65
Permissible temperatures
- Ambient filled/unfilled -20 ... +60 °C
- Medium maximum +100 °C
Further technical data see data sheet PV 14.03
3.6 Model PGT43HP.100 / PGT43HP.160
Working pressure
- Steady Full scale range
- Fluctuating 0.9 x full scale range
- Overload capability 40, 100 and 400 bar
Temperature influence
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP protection class
- Housing IP 54 per EN 60 529 / IEC 60 529
- With liquid filling IP 65
Permissible temperatures
- Ambient filled/unfilled -20 ... +60 °C
- Medium maximum +100 °C
Further technical data see data sheet PV 14.07