Wika 732.15.100 Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
Specications Models 891.44 and 892.44 (Ex Version)
Power supply UB
for Non-Ex version DC 12 V < UB ≤ 30 V
for Ex version see the section ‚Ex protection‘!
Permissible residual ripple
% of span/10 V
≤ 0.1
Supply voltage eect % ss ≤ 10
Output signal 4 … 20 mA, 2-wire system
Permissible max. load R
A for Non-Ex versions, Model 891.44:
R
A ≤ (UB - 12 V) / 0.02 A with RA in Ω and UB in Volt
for Ex versions, Model 892.44:
R
A ≤ (UB - 14 V) / 0.02 A with RA in Ω and UB in Volt
Eect of load % of span ≤ 0.1
Output signal adjustment
Zero point, electrical A
djustment of zero point through brief bridging of terminals 5 and 6,
or using the „scale selection switch“ option, selectable via button
1)
Scale selection 4 scales selectable via BCD switch
Linearity % of span ≤ 1.0 (limit point calibration)
Permissible
ambient temperatures °C -40 … +80, -40 … +60 with oxygen
Compensated temp. range °C -40 … +80
Temperature coecients in
compensated temp. range
Mean TK of zero
% of span/10 K
≤ 0.3
Mean TK of span
% of span/10 K
≤ 0.3
Ex protection according to EC-Type Examination Certicate
BSV 08 ATEX E 018 X for Model 892.44
Ex certication EEx II 2G EEx ia IIC T6
Conformity specications
Power supply U
i DC 14 … 30 V
Short circuit rating I
i mA max. 100
Rating P
i W max. 1
Internal capacitance C
i nF 12
Internal inductance L
i mH negligible
Medium temperature °C -40 … +80, -40 … +60 with oxygen
Ambient temperature °C -40 … +60 (T6)
CE-Conformity interference emission and immunity per EN 61326
Wiring L-connector (screw terminals up to 2.5 mm²)
Wiring protection protected against reverse polarity and overvoltage
Ingress protection IP 65 per EN 60529 / IEC 529
Wiring details,
2-wire
11592011.04 06/2014 GB/D/F/I
GB
WIKA operating instructions dierential pressure gauge models 712.15.100, 732.15.100
11
8. Transmitter for level measurement
1) Only possible within 30 seconds of connecting the supply voltage
Earth, connected
to case 2)
U
B+/Sig+
Terminals 3, 4, 5 and 6: only for internal
application
0V/Sig-
2) This connection must not be used
for equipotential bonding. The
instrument must be incorporated in
the equipotential bonding via the
process connection.
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 67 68

Comentarios a estos manuales

Sin comentarios