Wika GCS-1 Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9WIKA operating instructions gas cylinder scale model GCS-1
GB
11145676.05 11/2011 GB/D/F/E
Explanation of symbols
Before mounting and commissioning the instrument, ensure
you read the operating instructions!
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directi-
ves.
ATEX European Explosion Protection Directive
(Atmosphère = AT, explosible = Ex)
Instruments bearing this mark comply with the requirements of the
European Directive 94/9/EC (ATEX) on explosion protection.
3. Specications
3.1 Measuring ranges
Weight
lbs
Measuring range 0 ... 60 0 ... 100 0 ... 300
Overload 0 ... 250 0 ... 300 0 ... 750
kg
Measuring range 0 ... 27.2 0 ... 45.4 0 ... 136.1
Overload 0 ... 115 0 ... 130 0 ... 340
Other measuring ranges on request.
3.2 Output signal
Model Signal
GCS-1-A (2-wire) 4 ... 20 mA
GCS-1-G (4-wire) DC 0 ... 5 V
GCS-1-F (4-wire) DC 0 ... 10 V
Load
Model GCS-1-A: ≤ (power supply - 10 V) / 0.02 A
Model GCS-1-G: > 5 kΩ
Model GCS-1-F: > 10 kΩ
2. Safety / 3. Specications
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 75 76

Comentarios a estos manuales