19WIKA operating instructions pressure transmitter model O-10
GB
11613017.04 05/2013 GB/D/F/E
3. Specications
3.14 Electrical connections model O-10 (T)
Available connections
Electrical connection Ingress
protection
Wire cross-
section
Cable
diameter
Cable
lengths
Angular connector DIN 175301-803 A IP 65 - - -
Angular connector DIN 175301-803 C IP 65 - - -
Circular connector M12 x 1 (4-pin) IP 67 - - -
Metri-Pack series 150
1)
IP 67
-
- -
Cable outlet, unshielded
2)
IP 67 0.14 mm
2
3.4 mm 2 m , 5 m
Cable outlet, shielded IP 67 0.14 mm
2
4.3 mm 2 m , 5 m
1) for model O-10 (T) only possible from measuring range 0 ... 60 bar
2) up to a maximum of 80 °C permitted
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors
that have the appropriate ingress protection.
Short-circuit resistance
S
+
vs. 0V
Reverse polarity protection
U
B
vs. 0V
Overvoltage protection
DC 36 V
Insulation voltage
DC 750 V