Max. torque screws mounting strap 30 Nm
Max. torque screws socket external housing 5 Nm (3.688 lbf ft)
Weight approx. 4.2 4 .5 kg (9.26 9.92 lbs), depending on
process tting
Output variable
Output
- Signal digital output signal, Foundation Fieldbus protocol
- Physical layer according to IEC 61158-2
Channel Numbers
- Channel 1 Primary value
- Channel 2 Secondary value 1
- Channel 3 Secondary value 2
- Channel 4 Temperature value
Transmission rate 31.25 Kbit/s
Current value 10 mA, ±0.5 mA
Dynamic behaviour output
Run-up time 20 s
I
63 %
100 %
t
t
1
t
2
Fig. 51: Presentation of the dead time t
1
and the time constant t
2
Version, nominal measuring range Dead time t
1
Time constant t
2
Basic version 10 bar and 30 bar 100 ms 250 ms
Basic version 100 mbar 100 ms 180 ms
Basic version 500 mbar 100 ms 180 ms
Basic version, 3 bar 100 ms 180 ms
Basic version 16 bar and 40 bar 100 ms 180 ms